Installations & research
 
projects
 


 

   
Sveg
  
  
Installation in Sveg, middle of Sweden.

  Special research in cooperation with Vindforsk, CombiTech and
  HoloOptics. The project will study the icing effects on different
  altitudes (15m - 300m). Using four T26 Icing Rate Sensors and
  one T23 Clear-Ice Indicator™ on a nearby wind power plant.

  
The sensors are now replaced by T44 and T41.



  
Härnösand
  
Special Research projects

  Installation at the wind power plant in Härnösand.

 


  Special research in cooperation with Vindforsk, Hemab,
  Skelleftekraft and HoloOptics. The project will determine how ice
  is spreading on the wind power wings by using optical Ice Marker™
  supplied by HoloOptics. The project will also investigate effect
  losses due to icing.



  
Aapua & Bliekevare wind Farms

  Installation at Aapua Wind Farm at the polar circle.

  One T23 Clear-Ice Indicators™ is installed at a wind power farm
  In Aapua in northern Sweden.

  
The sensors are now replaced by T41.



  
EA Technology

  Installation at DeadWater, northern England.

  From January 2008 one T26 Icing Rate Sensor is installed
  by EA Technology.



  
Bulgarian Meteorological Inst.

  Installation at Mount Moissala 2925m asl.

  From the middle of January 2007 one T26 Icing Rate Sensor is tested
  by the Bulgarian Meteorological institute.  



  
Finnish Meteorological Institute
  
(FMI)
   
 
Installation at FMI Test Site at Luosto, northern Finland.

 


  From November 2007 one T26 Icing Rate Sensor is tested  
  
by FMI. Results will be presented eventually.



  
MeteoFrance

 
Installation at MeteoFrance in Paris and Mont Aigoual
  1567m asl.

 

 
MeteoFrance used one T26 Icing Rate Sensor for tests in
  December 2006.



  
MeteoSuisse

 
Installation at MeteoSuisse Guetsch 2287m asl.

 










  From the middle of November 2006 one T26 Icing Rate Sensor is
  tested
by MeteoSuisse.



  
Royal Institute of Technology
 
(KTH)
  
Installation at Royal Institute of technology.  

  At the Royal Institute of Technology (KTH) in Stockholm some
  Clear-Ice Indicators™ with heat sensors in the probe was tested in
  light icing conditions...

 
  -- Read diagram --



  
Narvik

  Installation in Narvik, 200km north of the polar circle.

 








              
  -- Read diagram --


 
The Narvik University used the T23 Clear-Ice Indicators™ beta
  version as icing rate sensor from the season 2005. Today two
  T23 Clear-Ice Indicators™ are installed on a wind power plant
  close to Narvik.

  
The sensors are now replaced by a T44. One T44 is also installed at
  a measurement mast close to Narvik
 

  Narvik, Norway is situated 200km north of the polar circle.
  The position makes it very prone to icing, as mild winds with high
  moisture content reach the ...


  --
Read more --



  
Bromma Airport

  Installation at Bromma Airport, Stockholm..







              
  -- Read diagram --

 
During the winter 2004/2005 four T23 Clear Ice Indicators™ was
  used at Bromma Airport. They pointed in different directions
  to show …

 
 
-- Read more (In Swedish only) --



  
Tromsö

  Installation at Sandhaugen test field, 400km north of the polar
  Circle.








              
  -- Read diagram --


  Sandhaugen test field, Tromsö Norway is situated 400km north of
  the polar circle close to the North sea. From the beginning of
  December 2004 to May 2006, three T23 Clear-Ice Indicators™ beta
  version was used to indicate ice ...

  --
Read more --



 
Suorva

  Installation at the wind power plant in Suorva, 200km north
  of the polar circle.








          
  -- Read diagram --


  Four indicators was installed at the wind power plant in Suorva.
  The indicators was installed at the roof of the hub 40m of the
  ground...

  --
Read more --